AXIS#.VL.FBUNFILTERED

Description

AXIS#.VL.FBUNFILTERED reads the raw velocity feedback before any filters affect the value of this feedback.

Versions

Action Version Notes
Implemented 02-00-00-000
     

General Information

Type

Read Only

Units

Depends on AXIS#.UNIT.VROTARY or AXIS#.UNIT.VLINEAR, AXIS#.UNIT.ACCLINEAR

Rotary: rpm, rps, deg/s, (custom units)/s, rad/s

Linear: counts/s, mm/s, μm/s, (custom units)/s

Range

N/A

Default Value

N/A

Data Type

Float

Stored in Non Volatile Memory

No

Variants Supported

All variants are supported